Articles get their own address (shareable, back/forward work); the list is searchable by title and text, shows the article count, and is grouped into Applications and Troubleshooting & Guides via a hidden category line set from the editor. PDF export lays out at page width with page breaks, a title block and page numbers; Print uses the browser's vector print. Inline code is a pill that glows blue on hover, blockquotes no longer squeeze, and GitHub-style [!NOTE] alerts render. [[Badge]] syntax inside code spans is left alone.
980 B
980 B
Yellow:Remediation Red:Admin Required
WMI Namespace Fix
Symptoms: Software Center is blank, the ConfigMgr client shows Inactive, or the backup task sequence fails with WMI errors (0x80041003, 0x8004100e).
1. Verify the repository
Open an elevated PowerShell:
winmgmt /verifyrepository
WMI repository is consistent: skip to step 3.inconsistent: continue.
2. Salvage the repository
winmgmt /salvagerepository
Run /verifyrepository again. If it's still inconsistent, as a last resort:
winmgmt /resetrepository
3. Repair the ConfigMgr client
& "$env:WinDir\CCM\ccmrepair.exe"
Wait 10-15 minutes, then confirm Configuration Manager in Control Panel lists its actions.
4. Re-check in USMT Dash